
Factory Conventional DC12V Wired Fire Alarm
A Factory Conventional DC12V Wired Fire Alarm alerts building occupants audibly, and often visually, that a fire has been detected so they can evacuate. It is triggered either automatically by a connected detector or manually via a call point/break-glass unit. Fire alarms are installed throughout workplaces, factories, and public buildings as a mandatory early-warning measure. Gwa anyị ọnụọgụ ngwaahịa ị chọrọ na mba ị na-eziga ya, anyị ga-akwado ma ọ dabara, oge ọ ga-ewe, na ọnụahịa mbupụ.
- Ịrụ ọrụ onwe ya na njikwa: Automatic sounding on trigger
- Ike / Usoro ọrụ: Bell, siren, or electronic sounder
- Ike a na-ahụkarị: Audible coverage per floor/zone
| Ụdị Ngwaahịa | Ngwaọrụ Ịkwụsị Ọkụ |
| Ụdị Ngwaahịa Ntakịrị | Fire Alarm |
| Ọkwa Ịrụ Ọrụ Onwe Ya | Automatic sounding on trigger * |
| Ike / Usoro Ọrụ | Bell, siren, or electronic sounder * |
| Ike Ọ Na-arụ / Nha | Audible coverage per floor/zone * |
| Operating Voltage | DC12V |
| Working Current | ≤300mA |
| Alarm | Sound and Flash |
| SPL | 100dB ±3dB(1m in front) |
| Flash intensity | ≥1.2WS |
| Flash period | ≤1.5S |
| Flash light lifespan | ≥40000 times |
| Mounting | Wall mounted |
| Operating temperature | -10℃~55℃ |
| Humidity | ≤95%RH (No condensation) |
| Color | Red/Blue/White |
| Material | ABS plastic |
| Size | 122*72*36mm |
| Nnweta | Ọ dị / A na-eme ya dabere n'arịrịọ |
| Ngbanye Maka Mbupụ | Ngbanye kwesịrị njem ụgbọ mmiri dị |
| Nkwa Mmezi | Dịka usoro onye na-emepụta si dị — kwadoro mgbe ị na-ajụ ajụjụ |
* Nha a na-ahụkarị maka ụdị igwe a, ọ bụghị ọnụọgụ zuru ezu nke otu ngwaahịa a kapịrị ọnụ — kwadoro nkọwa kpọmkwem maka ihe ị chọrọ mgbe ị na-ajụ ajụjụ.
Tụnyere
Otu a si atụnyere ngwaahịa Ngwaọrụ Ịkwụsị Ọkụ ndị yiri ya
| Ụdị | Ịrụ Ọrụ Onwe Ya / Ike | Ihe E Ji Wuo Ya | Ike Ọ Na-arụ |
|---|---|---|---|
| Factory Conventional DC12V Wired Fire Alarm (ibe a) | Automatic sounding on trigger | — | Audible coverage per floor/zone |
| Fire Broadcast System | Manual or automatic voice announcement | — | Covers multiple zones/floors of a building |
| 11 Kg DCP Type Fire Extinguisher | Manual operation, squeeze lever | Mild steel or aluminium cylinder | 11 kg |
| 22.5 Kg Trolley Mounted CO2 Fire Extinguisher | Manual operation, squeeze lever | Mild steel or aluminium cylinder | 225 kg |
Ị nwekwara ike chọọ
Ngwaahịa Yiri Ya
Ajụjụ Ndị Na-azụ Ahịa
Ajụjụ gbasara Factory Conventional DC12V Wired Fire Alarm
Ee — a na-ahazikarị ike, nkọwa ike na akụrụngwa nkwado maka Factory Conventional DC12V Wired Fire Alarm dabere n'ihe ị chọrọ. Gwa anyị ọnụọgụ ngwaahịa ị chọrọ na mba ị na-eziga ya mgbe ị na-ajụ ajụjụ.
A na-ebubata mbupụ ọ bụla n'ụzọ ga-eme ka o guzosie ike n'oge njem, ya na akwụkwọ mbupụ a chọrọ; a na-etinye akwụkwọ nkọwa ọrụ ebe o kwesịrị. A na-akwado usoro nkwado nrụnye mgbe e mesịrị ere n'iwu ahịa.
Ngwaahịa a dị maka mbupụ gaa mba karịrị 67 gafere Afrịka, Eshia, Middle East na Latin America. Kwadoro mba ị na-eziga ya mgbe ị na-arịọ ọnụahịa.
Yes. For tender and bulk institutional orders of the Factory Conventional DC12V Wired Fire Alarm, we quote against the exact technical specification in your tender document and align production and dispatch with your award timeline.




